page_banner

Cardiovascular

  • CK-MB Rapid Test

    CK-MB Rapid Test

    REF:PMDFL

    Specification:1 test/kit;5 tests/kit;10tests/kit;20tests/kit;25tests/kit;

    30 tests/kit; 40 tests/kit; 50 tests/kit

    Clinical Significance:diagnosis of myocardial injury;evaluation of myocardial infarction

    Performance Parameter:Sample:serum/plasma/whole blood

    Sample dosage:100 ul

    Linear range:3-80ng/mL

    LOD:<5.0 ng/ mL

    Detection time( min):10min

    Applicable Department: Chest pain center, emergency department, cardiology department, ICU/CCU, etc

    Supporting Instruments:PMDT9000;PMDT9100

  • MYO Rapid Test

    MYO Rapid Test

    REF:PMDFK

    Specification:1 test/kit;5 tests/kit;10tests/kit;20tests/kit;25tests/kit;

    30 tests/kit; 40 tests/kit; 50 tests/kit

    Clinical Significance:diagnosis of myocardial injury;evaluation of myocardial infarction

    Performance Parameter:Sample:serum/plasma/whole blood

    Sample dosage:70 μl

    Linear range:50-400ng/mL

    LOD:<70.00ng/ mL

    Detection time( min):10min

    Applicable Department: Chest pain center, emergency department, cardiology department, ICU/CCU, etc

    Supporting Instruments:PMDT9000;PMDT9100

  • S100 Rapid Test

    S100 Rapid Test

    REF:PMDFH

    Specification:1 test/kit;5 tests/kit;10tests/kit;20tests/kit;25tests/kit;

    30 tests/kit; 40 tests/kit; 50 tests/kit

    Clinical Significance:makers of brain injury

    Performance Parameter:Sample:serum/plasma

    Sample dosage:70 μl

    Linear range:0.08ng/mL-10.00ng/mL

    LOD:<0.11ng/ mL

    Detection time( min):15min

    Applicable Department:neurology department, emergency department, psychiatric services

    Supporting Instruments:PMDT9000;PMDT9100

  • cTnI/Myo/CK-MB Rapid Test

    cTnI/Myo/CK-MB Rapid Test

    REF:PMDFI

    Specification:1 test/kit;5 tests/kit;10tests/kit;20tests/kit;25tests/kit;

    30 tests/kit; 40 tests/kit; 50 tests/kit

    Clinical Significance:diagnosis of myocardial ingury;ecaluation of myocardial infarction

    Performance Parameter:Sample:serum/plasma/whole blood

    Sample dosage:100 μl

    Linear range:cTnI: [0.3,25] ng/ml;

    Myo:  [25,500] ng/ml;

    CK-MB:[2.5,300] ng/ml

    LOD:cTnI:<1.00ng/ mL;

    Myo:<70.00ng/ mL;

    CK-MB:<5.00ng/ mL.

    Detection time( min):15min

    Applicable Department: Chest pain center, emergency department, cardiology department, ICU/CCU, etc

    Supporting Instruments:PMDT9000;PMDT9100

  • ST2 Rapid Test

    ST2 Rapid Test

    REF:PMDFD

    Specification:1 test/kit;5 tests/kit;10tests/kit;20tests/kit;25tests/kit;

    30 tests/kit; 40 tests/kit; 50 tests/kit

    Clinical Significance:early recognition;risk evaluation;prognostic assessment of  heart failure

    Performance Parameter:Sample:serum/plasma/whole blood

    Sample dosage:70 μl

    Linear range:5.00-200.00ng/mL

    LOD:<35.00ng/ mL

    Detection time( min):15min

    Applicable Department: Chest pain center, emergency department, cardiology department, ICU/CCU, etc

    Supporting Instruments:PMDT9000;PMDT9100

  • ST2/NT-proBNP Rapid Test

    ST2/NT-proBNP Rapid Test

    REF:PMDFE

    Specification:1 test/kit;5 tests/kit;10tests/kit;20tests/kit;25tests/kit;

    30 tests/kit; 40 tests/kit; 50 tests/kit

    Clinical Significance:comprehensive management of heart failure

    Performance Parameter:Sample:serum/plasma

    Sample dosage:100 μl

    Linear range:sST2: 5.00-200.00ng/mL

    NT-proBNP: 100.00-20000.00pg/mL

    LOD:sST2:<35.00ng/ mL

    NT-proBNP:<300.00 pg/mL

    Detection time( min):15min

    Applicable Department: Chest pain center, emergency department, cardiology department, ICU/CCU, etc

    Supporting Instruments:PMDT9000;PMDT9100

  • cTnI Rapid Test

    cTnI Rapid Test

    REF:PMDFJ

    Specification:1 test/kit;5 tests/kit;10tests/kit;20tests/kit;25tests/kit;

    30 tests/kit; 40 tests/kit; 50 tests/kit

    Clinical Significance:makers of myocardial injury

    Performance Parameter:Sample:serum/plasma/whole blood

    Sample dosage:70 μl

    Linear range:0.2ng/mL-40.00ng/mL

    LOD:<1ng/ mL

    Detection time( min):10min

    Applicable Department: Chest pain center, emergency department, cardiology department, ICU/CCU, etc

    Supporting Instruments:PMDT9000;PMDT9100

  • NT-proBNP Rapid Test

    NT-proBNP Rapid Test

    REF:PMDFB

    Specification:1 test/kit;5 tests/kit;10tests/kit;20tests/kit;25tests/kit;

    30 tests/kit; 40 tests/kit; 50 tests/kit

    Clinical Significance:diagnosis of heart failure; identification of dyspnea

    Performance Parameter:Sample:serum/plasma/whole blood

    Sample dosage:100 μl

    Linear range:30.00pg/mL-30000.00pg/mL

    LOD:<300.00 pg/mL

    Detection time( min):15min

    Applicable Department: Chest pain center, emergency department, cardiology department, ICU/CCU, etc

    Supporting Instruments:PMDT9000;PMDT9100

  • D-Dimer Rapid Test

    D-Dimer Rapid Test

    REF:PMDFA

    Specification:1 test/kit;5 tests/kit;10tests/kit;20tests/kit;25tests/kit;

    30 tests/kit; 40 tests/kit; 50 tests/kit

    Clinical Significance:activation evaluation of coagulation and fibrinolysis

    Performance Parameter:Sample:plasma/whole blood

    Sample dosage:70 μl

    Linear range:200.00ng/mL-5000.00ng/mL

    LOD:<500ng/mL

    Detection time( min):10min

    Applicable Department:Chest pain center, emergency department, cardiology department, ICU/CCU, etc

    Supporting Instruments:PMDT9000;PMDT9100

  • BNP Rapid Test

    BNP Rapid Test

    REF:PMDFC

    Specification:1 test/kit;5 tests/kit;10tests/kit;20tests/kit;25tests/kit;

    30 tests/kit; 40 tests/kit; 50 tests/kit

    Clinical Significance:diagnosis of heart failure; identification of dyspnea

    Performance Parameter:Sample:plasma

    Sample dosage:70 μl

    Linear range:50.00pg/mL-3000.00pg/mL

    LOD:<100.00 pg/ml

    Detection time( min):15min

    Applicable Department:Chest pain center, cardiology department, ICU/CCU, etc

    Supporting Instruments:PMDT9000;PMDT9100